SW-5D Time-Base Frequency Instrument with 7 Selectable Standard Outputs 1.3" OLED Display and OCXO Temperature Deviation ≤ 0.05 ppm

SW-5D Time-Base Frequency Instrument with 7 Selectable Standard Outputs 1.3" OLED Display and OCXO Temperature Deviation ≤ 0.05 ppm

Marka Adı: GENY
Model Numarası: SW-5D
Adedi: 1
fiyat: negotiate rates
Ödeme Şartları: T/T, L/C, D/P, T/T
Tedarik Yeteneği: 10 adet/1 ay
Detay Bilgi
Menşe yeri:
ÇİN
Sertifika:
ISO, CE
Test referans sıcaklığı:
25°C
Sıcak başlangıç:
27s
sıcak başlangıç:
1s
Soğuk Başlangıç ​​Hassasiyeti:
-148dBm
Varsayılan Kristal Osilatör Saati Darbe Frekansı:
625khz/s
Kristal Osilatör Saati Darbe Frekans Doğruluğu::
≤4 × 10-7
Ambalaj bilgileri:
Kontrplak Kılıfları
Yetenek temini:
10 adet/1 ay
Vurgulamak:

7 selectable standard outputs Time-Base Frequency Instrument

,

1.3" OLED display Frequency Standard Instrument

,

OCXO temperature deviation ≤ 0.05 ppm Clock Verification Instrument

Ürün Tanımı
SW-5D Time-Base Frequency Instrument
Precision instrument designed for electricity meter clock verification with high-stability time base and GPS synchronization.
Key Features
  • High-stability OCXO time base; frequency accuracy ≤ 4*10-7
  • GPS time sync and correction via Ethernet (second-level synchronization)
  • 7 selectable standard outputs: 0.5 Hz / 1 Hz / 100 kHz / 500 kHz / 625 kHz / 1 MHz / 2 MHz
  • Pulse input measurement: 0.1 Hz-1 MHz, with automatic daily time error calculation
  • 1.3" OLED display, simple keypad, remembers last output frequency
Technical Specifications
Time Base OCXO; temperature deviation ≤ 0.05 ppm at -20℃ to +60℃ (ref 25℃)
Default Output 625 kHz; 50% duty cycle; levels: High 4.5 V / Low 0.11 V (typ.)
GPS Performance Cold start ~29 s, hot start ~1 s; sensitivity: capture -148 dBm / tracking -165 dBm
Error Test Duration 1-100 s (default 60 s); displays measured input frequency and daily time error
I/O F-IN (frequency measurement), F-OUT (standard frequency output)
Communications RJ45 Ethernet (default IP 192.168.1.199, port 1234), RS-232 (reserved)
Power AC 220 V (fused), chassis ground terminal
Applications
  • Accuracy verification of internal clocks in multifunction energy meters
  • Laboratory and field time-base standard output and pulse frequency measurement
  • GPS-based time synchronization for calibration systems
Installation Guide
  • Connect F-OUT to system comm board J2 (adapter cable included)
  • Connect S-ANT to outdoor antenna for GPS time sync
  • Use Ethernet for IP/port configuration and standard time read/write
Ordering Information
  • Model: SW-5D Time-Base Frequency Instrument
  • Standard accessories: output adapter cable, AC power cord, user manual
  • Options: GPS antenna and extension cable, RS-232 cable